Ts1162 Installation Manual May 2026
This guide outlines the physical installation, wiring, and addressing procedures for the TS1162.
If the device is more than 100 meters from the main panel, it is recommended to use an external 12V power supply while maintaining a common negative (–) reference with the LAN. 3. Configuration (Addressing & Termination) ts1162 installation manual
If the TS1162 is the last device on a long RS-485 cable run, set the termination DIP switch (typically Switch 8) to the 'ON' position to prevent data signal reflections. 4. System Integration This guide outlines the physical installation, wiring, and
The is a 3-LED Remote Arming Station (RAS) designed for use with Challenger security systems. Rated at IP67 , this robust keypad is suitable for both indoor and outdoor installations, including harsh, dusty, or wet environments. Configuration (Addressing & Termination) If the TS1162 is
Ensure the mounting surface allows the rear tamper lever to be fully depressed when the unit is secured. Enclosure Removal: Undo the retaining screws at the bottom of the keypad.
The TS1162 is designed for surface mounting. Its durable plastic housing allows it to be placed up to 1.5 km away from a Challenger panel or Intelligent Access Controller via the RS-485 LAN.
Use the internal DIP switches (usually 1–4) to set the RAS address (1 through 16). Refer to your specific Challenger panel manual for the binary address table.